ROOFING INSTALLATION GUIDELINES
 
1. Minimum Roof Slope: 10 Degrees
 
2. Recommended Purlins Distance:
Thickness (mm) Purlin Distance
1.5 mm
2.0 mm
2.5 mm
0.60 m
0.70 m to 0.80 m
0.80 m to 1.0 m
 
3. Length
3.1 Commercial Sizes:

8, 10, 14 and 16 feet long

3.2 Long Span  
 
4. Nominal Width: mm (inches)
  Profile Width mm(inches)
4.1 Corrugated 990 mm (38.97 inches)
4.2 Rib Type 800 mm (31.49 inches)
4.3 Flat Shet 914 mm (35.98 inches)
 
5. Effective width in mm(inches)
 
Side Lapping
 
CORRUGATED
RIB
Profile
2 1/2
2
1 1/2
1 Standard Rib Type
Corrugated
800
(31.49)
834
(32.83)
870
(34.24)
NA
Rib Type
NA
NA
NA
740 (29.13 inches)
 
6. Net Covered Area
CORRUGATED
RIB
effective width 
2 1/2 Lapping
2 Lapping
1 1/2 Lapping
1 Lapping
(standard)
linear foot 2.63 2.74 2.85  2.43
linear meter 0.800 0.834 0.87 0.740
 
7. Hardware Accessories (Synchromated or Stainless)
7.1 Tekscrew w/ cyclonic washer and neoprene rubber
7.2 Blind Rivets  
 
8. Sealants: Silicone Sealant
 